REGLP

View Navigation

REGLP

The REGLP F7-D7 series comprises an REGL base unit freewheel, combined with an F7 Fixing Flange and a D7 Cover Flange.

Torque is transmitted to the inner race via a key from the shaft and the outer race by means of an external key. Shaft tolerance must be h6/j6.

The unit is supplied with two paper gaskets for use between outer race and sealing cover/fixing plates. Failure to use the gaskets may cause loss of lubricant and subsequent rapid failure of the freewheel.

Prior to use, the freewheel must be lubricated.

The REGL F7-D7 unit is a self-sealed design.

For pre-greased lubrication options the REGLG range is available, contact Renold Sales for assistance.

Close